HomeResourcesDevices & Calibration
Device Monitoring & Calibration
Health of on-board GPS, RFID and weighing equipment across the fleet.
More filters
GPS Trackers
29 online
30
RFID Readers
28 online
30
Weighing Sensors
21 online · 3 calibration
30
Online
78
86.7% of devices
Warning
4
Fault
2
Offline
3
Calibration Due
2
within 7 days
Calibration Overdue
1
Device status distribution · 90 devicesLast poll 10:24 AST
■ Online 78■ Warning 4■ Calibration 3■ Fault / Offline 5
Device Registry
| Device ID | Device Type | Vehicle | Status | Last Communication | Calibration | Last Calibrated | Next Due |
|---|---|---|---|---|---|---|---|
| WGH-026 | Weighing Sensor | TRK-026 | Calibration Overdue | 27 Oct 10:22 | Overdue | 18 Apr 2026 | 18 Oct 2026 |
| GPS-021 | GPS Tracker | TRK-021 | Offline | 27 Oct 07:58 | N/A | — | — |
| WGH-021 | Weighing Sensor | TRK-021 | Fault | 27 Oct 07:58 | Valid | 11 Aug 2026 | 11 Feb 2027 |
| WGH-007 | Weighing Sensor | TRK-007 | Warning | 27 Oct 10:23 | Valid | 05 Sep 2026 | 05 Mar 2027 |
| WGH-012 | Weighing Sensor | TRK-012 | Calibration Due | 27 Oct 10:20 | Due | 02 May 2026 | 02 Nov 2026 |
| RFR-026 | RFID Reader | TRK-026 | Warning | 27 Oct 10:22 | N/A | — | — |
| RFR-001 | RFID Reader | TRK-001 | Online | 27 Oct 10:24 | N/A | — | — |
| WGH-005 | Weighing Sensor | TRK-005 | Online | 27 Oct 10:24 | Valid | 02 Oct 2026 | 02 Apr 2027 |
| GPS-005 | GPS Tracker | TRK-005 | Online | 27 Oct 10:24 | N/A | — | — |
| WGH-014 | Weighing Sensor | TRK-014 | Online | 27 Oct 10:23 | Valid | 20 Jul 2026 | 20 Jan 2027 |
Showing 1–10 of 90 devices
‹123…›
Device Alerts
7 active
Calibration Required
WGH-012 · TRK-012 · due 02 Nov 2026
Failed Calibration
WGH-019 · TRK-019 · deviation 3.8% > 2% tolerance
Suspicious Weight Reading
WGH-007 · BIN-028 · 1,940 kg on 1,100L bin
Sensor Fault
WGH-021 · load cell signal lost
Offline Device
GPS-021 · TRK-021 · no data for 2 h 26 m
Missing RFID Reading
RFR-001 · BIN-061 at CP-109
Missing GPS Data
GPS-014 · 4 min gap on RT-SLM-04
WGH-026 Weighing SensorCalibration Overdue
Device details
Device information
- Model
- LoadSense LC-4 dual load cell
- Serial
- LC4-22-08817
- Firmware
- 2.6.1
- Installed
- 14 Feb 2025
Vehicle & communication
- Associated vehicle
- TRK-026 · 9015 GGW
- Operator
- Averda
- Communication
- Online
- Last message
- 27 Oct 2026 10:22:41
Calibration history
- Calibration overdueDue 18 Oct 2026 · 9 days late
- Passed · deviation 0.6%18 Apr 2026 · Saudi Weighing Lab
- Passed · deviation 0.9%20 Oct 2025 · Saudi Weighing Lab
Recent faults & notes
Zero drift +4 kg
22 Oct 2026 · auto-detected
Vehicle kept off weighed routes until recalibrated. Technician visit requested for 29 Oct. — T. Hussain